Product characteristics
Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1
Process connection threaded connection M18 x 1,5 internal thread
Application
Special feature Gold-plated contacts
Media water; glycol solutions; air; oils
Note on media low-viscosity oils with viscosity: ≤ 40 mm²/s (40 °C)
high-viscosity oils with viscosity: > 40 mm²/s (40 °C)
Medium temperature [°C] -20…90
Pressure rating [bar] 100
Pressure rating [Mpa] 10
MAWP (for applications
according to CRN)
[bar] 100
Electrical data
Operating voltage [V] 18…30 DC
Current consumption [mA] < 100
Protection class III
SA5000
Flow sensor
SAD10XDBFRKG/US-100
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — SA5000-01 — 13.04.2023 —
Reverse polarity protection yes
Power-on delay time [s] 10
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1
Outputs
Total number of outputs 2
Output signal switching signal; analogue signal; frequency signal; IO-Link; (configurable)
Electrical design PNP/NPN
Number of digital outputs 2
Output function normally open / normally closed; (parameterisable)
Max. voltage drop switching
output DC
[V] 2.5
Permanent current rating of
switching output DC
[mA] 250
Number of analogue outputs 1
Analogue current output [mA] 4…20; (scalable)
Max. load [Ω] 350
Short-circuit protection yes
Type of short-circuit
protection pulsed
Overload protection yes
Frequency of the output [Hz] 0…1000
Measuring/setting range
Probe length L [mm] 45
Operating mode relative; absolutely liquid; absolutely gaseous;
(absolute: reference measurement recommended)
Note on factory setting Operating mode: relative
Temperature monitoring
Measuring range [°C] -20…90
Resolution [°C] 0.2
Liquid media – absolute operating mode
Setting range [m/s] 0.04…3
Greatest sensitivity [m/s] 0.04…3
Liquid media – relative operating mode
Setting range [m/s] 0.04…6
Greatest sensitivity [m/s] 0.04…3
Gases – operating mode “absolute”
Setting range [m/s] 0…100
Greatest sensitivity [m/s] 30…100
Gases – operating mode “relative”
Setting range [m/s] 0…200
Greatest sensitivity [m/s] 30…100
Accuracy / deviations
Temperature drift [cm/s x 1/K] 0,003 m/s x 1/K (< 20 °C; > 70 °C)
SA5000
Flow sensor
SAD10XDBFRKG/US-100
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — SA5000-01 — 13.04.2023 —
Temperature gradient [K/min] 100
Absolute operating mode
Repeatability 0,05 m/s; (water; flow velocity: 0,05…3 m/s)
Relative operating mode
Accuracy ± (7 % MW + 2 % MEW); (for relative mode in the range of maximum
sensitivity under the following conditions:; water: 20…70 °C; inlet
length: 1.5 m; DN25 (DIN 2448); mounting position according to
instructions; Accuracy can differ for other media and mounting positions.)
Repeatability 0,05 m/s; (water; flow velocity: 0,05…3 m/s)
Temperature monitoring
Temperature drift ± 0,005 K/°C
Accuracy [K] ± 0,3 / ± 1; (water; flow velocity: 0,3…3 m/s / air; flow velocity: > 10 m/s)
Response times
Response time [s] 0.5; (T09; water; glycol: 0,8 s; air: 7 s; oil: 1,8 s; each T09)
Temperature monitoring
Dynamic response T05 / T09 [s] 1,5 (T09); (water; flow velocity: 0,3…3 m/s)
Software / programming
Parameter setting options hysteresis / window; normally open / normally closed; switching logic; current/
frequency output; medium selection; Damping; Teach function; display can be
rotated and switched off; standard unit of measurement; process value colour
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9
Profiles Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis
SIO mode yes
Required master port type A
Process data analogue 2
Process data binary 2
Min. process cycle time [ms] 3
Supported DeviceIDs Type of operation DeviceID
Factory setting / ModE = (REL) 533
ModE = (LIQU) 540
ModE = (GAS) 547
Operating conditions
Ambient temperature [°C] -40…80
Storage temperature [°C] -40…100
Protection IP 65; IP 67
Tests / approvals
EMC DIN EN 60947-5-9
Shock resistance DIN EN 60068-2-27 50 g (11 ms)
Vibration resistance DIN EN 60068-2-6 20 g (10…2000 Hz)
MTTF [years] 132
SA5000
Flow sensor
SAD10XDBFRKG/US-100
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — SA5000-01 — 13.04.2023 —
UL approval UL Approval no. I003
File number UL E174189
Mechanical data
Weight [g] 314
Materials stainless steel (1.4404 / 316L); stainless steel (1.4310 / 301); PBT-GF20; PBT-GF30
Materials (wetted parts) stainless steel (1.4404 / 316L); Gasket: FKM
Process connection threaded connection M18 x 1,5 internal thread
Displays / operating elements
Display Display unit 6 x LED, green (%, m/s, l/min, m³/h, °C, 10³)
switching status 2 x LED, yellow
measured values alphanumeric display, red/green 4-digit
Remarks
Remarks MW = measured value
MEW = Final value of the measuring range
Pack quantity 1 pcs.
Electrical connection
Connector: 1 x M12; coding: A; Contacts: gold-plated
سنسور فلو IFM مدل SI5000
سنسور فلومتر SI5000 یا فلو مانیتور IFM SI5000 آلمان جهت اندازه گیری سیالات و گازها همچون آب،روغن و سایر سیالات در لوله میباشد.رنج اندازه گیری برای مایعات از 3 تا 300 cm/s و برای گازها از 200 تا 3000 cm/s میباشد و میزان فلو و خروجی ها از طریق نمایشگرهای تعبیه شده روی فلومتر قابل رویت میباشد. فلومتر SI5000 دارای خروجی PNP و قابل تنظیم در حالت باز و بسته است.
اولین نفری باشید که دیدگاهی را ارسال می کنید برای “سنسور فلو IFM مدل SI5000” لغو پاسخ
برای ثبت نقد و بررسی وارد حساب کاربری خود شوید.
محصولات مشابه
سنسور فشار
برند IFM
برند IFM
برند IFM
برند IFM
برند IFM
برند IFM

















دیدگاهها
هیچ دیدگاهی برای این محصول نوشته نشده است.